Oxygen Cleaned Toggle Piston Vent Valve
Category:
Product Introduction
Oxygen Cleaned Toggle Piston Vent Valve
Oxygen Cleaned Toggle Piston Vent Valve, PN 10029030. Copper Alloy #377 body, PTFE Teflon sheet seal, stainless steel 303/304 components. Complies with CGA G-4.1 for liquid oxygen portable systems.

Product Overview
The HELiOS H850 Toggle Piston Vent Valve (Part Number 10029030, Rev A) is a manual hand-lever vent valve designed for the HELiOS Marathon H850 portable liquid oxygen system. All wetted components undergo professional oxygen service cleaning per CGA G-4.1, removing oil and hydrocarbon contaminants to eliminate fire and explosion risks in oxygen service.
This toggle lever valve adopts a compact assembly structure. It is used for venting and pressure relief during liquid oxygen filling, featuring fast response and reliable manual operation. Widely applied in aerospace and portable medical liquid oxygen supply systems.
| Part No. | Description | Material |
|---|---|---|
| 1 | TEFLON SHEET | PTFE |
| 2 | Spring | Stainless Steel Type 302/18-8 |
| 3 | FAB Nut Vent Valve H850 | ASTM B16 CA360 1/2Hard Brass |
| 4 | FAB Body Vent Valve H850 | ASTM B124 Copper Alloy #377 or ASTM B16 Copper Alloy #360 |
| 5 | Leven Vent Helios | Traix 1180-1510 or Zytel 101(Nylon 6/6) |
| 6 | FAB Vent Valve Toggle H850 | Stainless Steel Type 303 /18-8 |
| 7 | FAB Spring Torsion Vent Lever H750 | 300 Series Stainless Steel |
| size | A(In) | B(In) | C(In) | D(In) | E(In) | F(In) |
| 0.190 (4.83)-32 UNF-2B | 0.27 | 0.575 | 1.89 | 0.22 | 0.19 | 0.55±0.002 |
Key Features
Oxygen cleaned per CGA G-4.1: All wetted parts fully degreased for oxygen safety
Manual toggle lever structure: Simple and stable operation for venting & pressure relief
Copper Alloy #377 forged brass body: High strength and good air tightness
Composite PTFE + Kel-F 80 sealing system: Bubble-tight low leakage performance
Stainless steel 303 / 304 hardware: Anti-corrosion for long service life
Compact assembly, easy installation on portable liquid oxygen containers
Applications
- HELiOS Marathon H850 portable liquid oxygen supply system
- Medical liquid oxygen storage & venting assemblies
- Aerospace oxygen control and pressure relief equipment
- High purity gas vent and pressure release components
Technical Notes
- All wetted parts are cleaned for oxygen service in accordance with CGA G-4.1.
- Threads shall be coated with Krytox 240AC or EG2000 fluorinated grease.
- Leakage requirement: ≤49 cc/hr @97.75 psig; ≤180 cc/hr @85 psig. Stem leakage bubble tight (<5ccm) under 0.5 psig backpressure at outlet side.
- Burrs and sharp edges to be removed; all sharp corners broken.
- Compliance certificate supplied together with shipment.
- Refer to separate BOM under the same part number and revision for full component list.
Product keywords:
Oxygen Cleaned Toggle Piston Vent Valve
Related Products
Product Message















